DiLOG DL6403 1000A True RMS Clamp Meter

SKU: DILOGDL6403
  • Measures voltage, frequency, AC current, capacitance and temperature
  • True RMS measurement for current up to 1000A AC
  • Continuity and diode testing, peak hold and data hold functions
More Info
Typically ships in 2-4 working days

DiLOG DL6403 1000A True RMS Clamp Meter

The DiLOG DL6403 1000A True RMS Clamp Meter is a versatile clamp meter that can measure AC current (0.01 to 1000A), AC/DC voltage (0.1mV to 600V), resistance (0.1Ω to 40MΩ), capacitance (0.0001nF to 40mF), frequency (0.001kHz to 4kHz) and temperature (-40˚C to 1000˚C). The True RMS measurement function for AC values improves accuracy to within 3% for current and 2% for voltage whilst the resolution changes depending on the selected measurement range so the user always has a precise picture of circuit performance. Furthermore, continuity and diode testing are available for comprehensive inspections.

In addition to its impressive measurement ranges and accuracy, the DiLOG DL6403 also has several practical features for ease of use. Firstly, the bright, clear, 4000-count LCD screen means that results are clearly visible whilst the measurement rate of 2/sec ensures that the user gets real-time values on screen. Auto power-off helps save the battery. The device features both data hold and peak hold so the minimum and maximum value are saved and the user can freeze a reading on screen which is very useful when a measurement cannot be taken with the screen facing the operator. Data can be presented both digitally and in a bar-graph depending on the user's preference.

The 30mm 'teardrop' clamp can fit into tight spaces and the device is rated as Cat III up to 600V as well as meeting all applicable safety standards. The DiLOG DL6403 comes provided with a thermocouple and test leads as well as a soft carry case for easy transportation. Overall, the impressive measurement ranges over most electrical variables make it a great instrument for inspecting electrical appliances and circuits.

Key Features

  • True RMS measurement for AC values
  • AC current range: 0.1A to 1000A
  • AC/DC voltage range: 0.1mV to 600V
  • Resistance range: 0.1Ω to 40MΩ
  • Capacitance range: 0.0001nF to 40mF
  • Frequency: 0.001kHz to 4kHz
  • Temperature: -40˚C to 1000˚C
  • Continuity and diode testing
  • Bright, 4000-count LCD screen
  • 2/sec measurement rate
  • Auto power-off after 20 minutes approx.
  • Data hold and peak hold
  • Supplied with thermocouple and test leads

What's In The Box?

  • Dilog DL6403 1000A True RMS AC/DC Clamp Meter
  • Dilog DL6403 1000A True RMS AC/DC Clamp Meter instruction booklet
  • Red/black test leads
  • Thermocouple
  • Soft carry case
Specification

General

  • Clamp size: 30mm jaw opening
  • Diode test: Test current of 0.3mA typical / open circuit voltage 1.5V DC
  • Continuity check: Threshold <35Ω / test current <1mA
  • Overrange indication: 'OL' is displayed
  • Measurement rate: 2/sec nominal
  • Input impedance: 10MΩ (VDC and VAC)
  • Display: 4000 count
  • AC current: 50/60Hz (AAC)
  • AC voltage bandwidth: 50/60Hz (VAC)
  • Operating temperature: -10˚C to +50˚C
  • Storage temperature: -30˚C to 60˚C
  • Relative humidity: up to 85%
  • Over voltage: Cat III up to 600V
  • Battery: 1 x 9V
  • Auto power-off: 20 minutes approx.
  • Dimensions: 229 x 80 x 49mm
  • Weight 303g

DC Voltage (Range; Resolution; Accuracy)

  • 400.0mV; 0.1mV; ±0.8 % of rdg ± 3 dgts
  • 4.000V; 0.001V; ±1.5 % of rdg ± 3 dgts
  • 40.00V; 0.01V; ±1.5 % of rdg ± 3 dgts
  • 400.0V; 0.1V; ±1.5 % of rdg ± 3 dgts
  • 600V; 1V; ±2.0 % of rdg ± 2 dgts 

AC Voltage - True RMS (Range; Resolution; Accuracy)

  • 400.0mV; 0.1mV; ±1.0 % of rdg ± 4 dgts
  • 4.000V; 0.001V; ±1.5 % of rdg ± 8 dgts
  • 40.00V; 0.01V; ±1.5 % of rdg ± 8 dgts
  • 400.0V; 0.1V; ±1.5 % of rdg ± 8 dgts
  • 600V; 1V; ±2.0 % of rdg ± 8 dgts
  • Maximum Input: 1000A

AC Current - True RMS (Range; Resolution; Accuracy)

  • 40.00A; 0.01A; ±2.8 % of rdg ± 10 dgts
  • 400.0A; 0.1A; ±2.8 % of rdg ± 8 dgts
  • 1000A; 1A ;±3.0 % of rdg ± 8 dgts
  • Maximum Input: 1000A True RMS

Resistance (Range; Resolution; Accuracy)

  • 400.0Ω; 0.1Ω; ±1.5 % of rdg ± 2 dgts
  • 4.000kΩ; 1Ω; ±1.5 % of rdg ± 2 dgts
  • 40.00kΩ; 10Ω; ±1.5 % of rdg ± 2 dgts
  • 400.0kΩ; 100Ω; ±2.5 % of rdg ± 5 dgts
  • 4.000mΩ; 1kΩ; ±3.5 % of rdg ± 10 dgts
  • 40.00mΩ; 10kΩ; ±3.5% of rag ±10 dgts
  • Input Protection: 250V DC or 250V AC

Diode Test

  • Test current: 0.3mA typical
  • Open circuit voltage: 1.5V DC typical
  • Overload protection: 250V DC or AC

Audible continuity

  • Audible threshold: Less than 35Ω
  • Test current: <1mA
  • Overload protection: 250V DC or 250VAC.

Capacitance (Range; Resolution; Accuracy)

  • 4.000nF; 0.001nF; ±5.0 % of rdg ± 30 dgts
  • 40.00nF; 0.01nF; ±5.0 % of rdg ± 20 dgts
  • 400.0nF; 0.1nF; ±3.0 % of rdg ± 5 dgts
  • 4.000uF; 0.001uF; ±3.0 % of rdg ± 5 dgts
  • 40.00uF; 0.01uF; ±3.0 % of rdg ± 5 dgts
  • 400.0uF; 0.1uF; ±4.0 % of rdg ± 10 dgts
  • 4.000mF; 0.001mF; ±4.5 % of rdg ± 10 dgts
  • 40.00mF; 0.01mF; ±5.0 % of rdg ± 10 dgts
  • Input Protection: 250V DC or 250V AC

Frequency (Range; Resolution; Accuracy)

  • 4.000kHz; 0.001kHz; ±1.5 % of rdg ± 2 dgts
  • Sensitivity: 5V rms minimum

Temperature (Range; Resolution; Accuracy)

  • -40 to 1000˚C; 1˚C; ±2.5 % of rdg ± 3˚C