AC voltage measurement (Range / Resolution / Accuracy 50 to 60Hz / Accuracy 60 to 5000Hz) - 600.0mV / 0.1mV / ±(1% + 3) / ±(2% + 3)
- 6.000V / 0.001V / ±(1% + 3) / ±(2% + 3)
- 60.00V / 0.01V / ±(1% + 3) / ±(2% + 3)
- 600.0V / 0.1V / ±(1% + 3) / ±(2% + 3)
- 1000V / 1V / ±(2% + 3) / ±(2% + 3)
Low-Pass Filter Voltage (Range / Resolution / Accuracy 50 to 60Hz / Accuracy 60 to 400Hz - 600.0mV / 0.1mV / ±(1% + 3) / +(2% + 3), -(6% - 3)
- 6.000V / 0.001V / ±(1% + 3) / +(2% + 3), -(6% - 3)
- 60.00V / 0.01V / ±(1% + 3) / +(2% + 3), -(6% - 3)
- 600.0V / 0.1V / ±(1% + 3) / +(2% + 3), -(6% - 3)
- 1000V / 1V / ±(2% + 3) / +(2% + 3), -(6% - 3)
DC Voltage Measurement (Range / Resolution / Accuracy - 6.000V / 0.001V / ±(0.09% + 2)
- 60.00V / 0.01V / ±(0.09% + 2)
- 600.0V / 0.1V / ±(0.09% + 2)
- 1000V / 1V / ±(0.09% + 2)
- Input impedance: 10MΩ (nominal), <100pF
- Normal mode rejection ratio: <60dB @ 50Hz
- Common mode rejection ratio: <120dB, 50Hz or 60Hz (1 k unbalance)
DC Voltage Millivolt Measurement (Range / Resolution / Accuracy - 600.0mV / 0.1mV / ±(0.01% + 1)
AC Current Measurement (45Hz to 1000Hz) (Range / Resolution / Accuracy / Burden Voltage - 400mA / 0.1mA / ±(1.5% + 2)1 / 2 mv/mA
- 60mA / 0.01mA / ±(1.5% + 2) / 2 mV/mA
DC Current Measurement (Range / Resolution . Accuracy Burden Voltage - 400mA / 0.1mA / ±(0.2% + 2) / 2 mv/mA
- 60mA / 0.01mA / ±(0.2% + 2) / 2 mV/mA
- Overload: 600mA for 2 minutes maximum
- Fuse protection for mA input: 0.44mA, 1000V, IR 10kA
- AC conversion: Inputs are AC-coupled and calibrated to the RMS value of sine wave input
11 kHz bandwidth Resistance measurement (Range / Resolution / Accuracy - 600.0Ω / 0.1Ω / ±(0.9% + 2)
- 6.000kΩ / 0.001kΩ / ±(0.9% + 2)
- 60.00kΩ / 0.01kΩ / ±(0.9% + 2)
- 600.0kΩ / 0.1kΩ / ±(0.9% + 2)
- 6.000MΩ / 0.001MΩ / ±(0.9% + 2)
- 50.0MΩ2 / 0.01MΩ / ±(1.5% + 3)
- Overload protection: 1000V RMS or DC
- Open circuit test voltage: <8.0V DC
- Short circuit current: <1.1mA
1Accuracies apply from 0% to 100% of range. 2Up to 80% RH Diode Test - Diode test indication: Display voltage drop 0.6V at 1mA nominal test current
- Accuracy: ±(2% + 3)
Continuity Test - Continuity indication: Continuous buzzer for resistance below 25Ω and off above 100Ω (Max reading = 1000Ω)
- Open circuit voltage: <8.0V
- Short circuit current: 1.0mA typical
- Overload protection: 1000V RMS
- Response time: >1ms
Frequency Measurement (Range / Resolution / Accuracy) - 99.99Hz / 0.01Hz / ±(0.1% + 1)
- 999.9Hz / 0.1Hz / ±(0.1% + 1)
- 9.999kHz / 0.001kHz / ±(0.1% + 1)
- 99.99kHz / 0.01kHz / ±(0.1% + 1)
>> Frequency Counter Sensitivity (Voltage / V AC sensitivity (RMS Sine Wave)1 5Hz to 100kHz / DC trigger levels1 to 20kHz2 - 600mV AC / 100mV / 150mV / n/a
- 6V / 1V / 1.5V / -400.0mV and 2.5V
- 60V / 10V / 36V / 1.2V and 4.0V
- 600V / 100V / n/a / 12V and 40V
- 1000V / 300V / n/a / 12V and 40V
1Mas input for specified accuracy + 10 x range (1000V max). Noise at low frequencies and amplitudes may affect accuracy 2Usable to 100kHz with full scale input Capacitance Measurement (Range / Resolution / Accuracy) - 1000nF / 1nF / ±(1.2% + 2)
- 10.00µF / 0.01µF / ±(1.2% + 2)
- 100.0µF / 0.1µF / ±(1.2% ± 90 counts)
- 9999µF / 1µF / ±(1.2% ± 90 counts)
Temperature Measurement (Range / Resolution / Accuracy) - -40°C to 537°C / 0.1°C / ±(1% + 10)
1Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument Insulation Specifications - Measurement range: 0.01MΩ to 2GΩ
- Test voltages: 50, 100, 250, 500, 1000V
- Test voltage accuracy: +20%, -0%
- Short-circuit test current: 1mA nominal
- Auto discharge: Discharge time
- Live circuit detection: Inhibit test if terminal voltage > 30V prior to initialisation of test
- Maximum capacitive load: Operable with up to 1µF load
Output Voltage (Test Voltage / Display Range / Resolution / Test Current 1 / Accuracy 1 / Display Range 2 / Resolution 2 / Test Current 2 / Accuracy 2 / Display Range 3 / Resolution 3 / Test Current 3 / Accuracy 3) - 50V (0% to 20%) / 0.01 to 6MΩ / 0.01MΩ / 1mA @ 50kΩ / ±(3% + 5) / 6 to 50MΩ / 0.1MΩ / 1mA @ 50kΩ / ±(3% + 5) / - / - / - / -
- 100V (0% to +20%) / 0.01 to 6MΩ / 0.01MΩ / 1mA @ 100kΩ / ±(3% + 5) / 6 to 60MΩ / 0.1MΩ / 1mA @ 100kΩ / ±(3% + 5) / 60 to 100MΩ / 1MΩ / 1mA @ 250kΩ / ±(1.5% + 5)
- 250V (0% to +20%) / 0.1 to 60MΩ / 0.1MΩ / 1mA @ 250kΩ / ±(1.5% + 5) / 60 to 250MΩ / 1MΩ / 1mA @ 250kΩ / ±(1.5% + 5) / - / - / - / -
- 500V (0% to +20%) / 0.1 to 60MΩ / 0.1MΩ / 1mA @ 500kΩ / ±(1.5% + 5) / 60 to 500MΩ / 1MΩ / 1mA @ 500kΩ / ±(1.5% + 5) / - / - / - / -
- 1000V (0% to +20%) / 0.1 to 60MΩ / 0.1MΩ / 1mA @ 1MΩ / ±(1.5% + 5) / 60 to 600MΩ / 1MΩ / 1mA @ 1MΩ / ±(1.5% + 5) / 0.6 to 2.0GΩ / 100MΩ / 1mA @ 1MΩ / ±(10% + 3)
General - Max voltage: 1000V
- Storage temperature: -40˚C to 60˚C
- Operating temperature: -20˚C to 55˚C
- Temperature coefficient: 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C
- Relative humidity (non-condensing): 0% to 95% @ 10 °C to 30 °C / 0% to 75% @ 30 °C to 40 °C / 0% to 40% @ 40 °C to 55 °C
- Vibration: Random, 2g, 5-500Hz per MIL-PRF-28800F, Class 2
- Radio frequency communication: 2.4 GHz ISM Band
- Radio frequency certification: FCC: T68-FBLE, IC: 6627A-FBLE
- IEC 61010-1: Pollution degree 2
- IEC 61010-2-033: Cat IV 600V / Cat III 1000V
- Batteries: Four AA batteries (NEDA 15A or IEC LR6)
- Battery life: 1000 hours
- Size (H x W x L): 10 x 100 x 203mm
- Weight: 550g
- Altitude: 2000m (operation) / 12000m (storage)
- Over-range capability: 11% of range except for capacitance which is 100%
- Frequency overload protection: <107 V Hz
- Fuse protection for mA input: 0.44A, 1000V, IR 10kA
|