Kewtech EZYPAT PAT Tester

SKU: KEWTEZYPAT
  • An ideal PAT tester for someone with a low appliance testing workload
  • Fast and slow 200mA continuity test, 250V and 500V insulation resistance test
  • Clear LCD screen turns green for PASS and red for FAIL
More Info
In Stock - Available Next Day
Choose Your Free Gift

Kewtech EZYPAT PAT Tester

The Kewtech EZYPAT PAT Tester is a handheld, battery-powered PAT tester capable of earth bond testing with a 200mA test current; insulation resistance testing with a 250V or 500V test voltage; substitute leakage measurement and polarity testing for extension leads. The tester has a 5s continuity test option for Class I appliances and extension leads whilst the lower insulation test voltage enables testing on surge-protected extension leads. To help ensure accuracy, a test lead nulling function allows the user to account for test lead resistance when testing appliances.

The Kewtech EZYPAT performs a pre-test status check of the appliance under assessment and testing of Class I appliances, Class II appliances and extension leads can be performed using three separate auto-test sequence buttons. The tester’s clear backlit display shows test results alongside a PASS/FAIL indication and even flashes green or red depending on whether an appliance has passed.

All necessary accessories are supplied including an earth lead, test probe, crocodile clip, extension lead adaptor, and carry case. It is extremely compact which is great for transporting around a large site. The Kewtech EZYPAT’s testing capabilities are ideal for those with lower-volume PAT testing responsibilities and it meets all pertinent regulatory standards.

Kewtech part number: EZYPAT

Key Features

  • Earth bond continuity test (200mA)
  • Quick and 5s continuity test
  • Insulation test (250V or 500V)
  • Substitute leakage current
  • Test lead resistance compensation
  • Auto-test sequences
  • Digital LCD screen
  • Green = PASS, red = FAIL
  • Battery operated
 EZYPATEZYPAT PlusSMARTPAT
200mA continuity test
250V Insulation Test
500V Insulation Test
Substitute Leakage Measurement
Polarity Check
110V Load and Run Test  
230V Load and Run Test  
Portable RCD Test    
Compatible with KEWPAT App    
Customisable Test Sequences    

What's In The Box?

  • Kewtech EZYPAT PAT Tester
  • Earth lead with probe and croc clip
  • Extension lead adapter
  • Carry bag with strap
  • Quickstart manual
  • End of line Cal Cert
Specification

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V / 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ / 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Applicable Standards

  • Safety: IEC/EN61010-1 CAT II 300V-instrument; IEC/EN61010-2-030; IEC/EN61010-031 CAT III 600V
  • EMC: EN61326-1, 2-2
  • Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec): Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)