Sauermann Si-CA 230 Multigas Industrial Gas Analyser (Choice Of Kit)
The Sauermann Si-CA 230 Multigas Industrial Gas Analyser (Choice Of Kit) provides users the choice of between 2, 3, 4, 5 or 6 sensors for their analyser. Each analyser comes equipped with O2 and CO with a number of other gas sensor available including NO, Low NO, NO2, SO2, CxHy, Low SO2, H2S providing an analyser suitable for commercial and industrial applications such as emissions monitoring of boilers, engines and other combustion applications. CO dilution auto range allows for measurements up to 50,000ppm.
Sauermann Si-CA 230 Flue Gas Analyser Comparison table
|
Number of Sensors |
O2 sensor |
CO Sensor |
NO sensor |
NO Low Range |
NO2 |
NO2 Low Range |
SO2 |
SO2 Low Range |
CxHy |
H2S |
Si-CA 230 Kit 2 |
2 |
✔ |
✔ |
|
|
|
|
|
|
|
|
Si-CA 230 Kit 3N |
3 |
✔ |
✔ |
✔ |
|
|
|
|
|
|
|
Si-CA 230 Kit 3NL |
3 |
✔ |
✔ |
|
✔ |
|
|
|
|
|
|
Si-CA 230 Kit 4ND |
4 |
✔ |
✔ |
✔ |
|
✔ |
|
|
|
|
|
Si-CA 230 Kit 4NS |
4 |
✔ |
✔ |
✔ |
|
|
|
✔ |
|
|
Si-CA 230 Kit 4NC |
4 |
✔ |
✔ |
✔ |
|
|
|
|
|
✔ |
|
Si-CA 230 Kit 4NLDL |
4 |
✔ |
✔ |
|
✔ |
|
✔ |
|
|
✔ |
|
Si-CA 230 Kit 4NLSL |
4 |
✔ |
✔ |
|
✔ |
|
|
|
✔ |
|
|
Si-CA 230 Kit 5NDS |
5 |
✔ |
✔ |
✔ |
|
✔ |
|
✔ |
|
|
|
Si-CA 230 Kit 5NDC |
5 |
✔ |
✔ |
✔ |
|
✔ |
|
|
|
✔ |
|
Si-CA 230 Kit 5NSC |
5 |
✔ |
✔ |
✔ |
|
|
|
✔ |
|
✔ |
|
Si-CA 230 Kit 5NSH |
5 |
✔ |
✔ |
✔ |
|
|
|
✔ |
|
|
✔ |
Si-CA 230 Kit 5NLDSL |
5 |
✔ |
✔ |
|
✔ |
|
✔ |
|
✔ |
|
|
Si-CA 230 Kit 6NDSC |
6 |
✔ |
✔ |
✔ |
|
✔ |
|
✔ |
|
✔ |
|
Si-CA 230 Kit 6NDSH |
6 |
✔ |
✔ |
✔ |
|
✔ |
|
✔ |
|
|
✔ |
Si-CA 230 Kit 6NLDLSLH |
6 |
✔ |
✔ |
|
✔ |
|
✔ |
|
✔ |
|
✔ |
The Si-CA 230 allows for predictive maintenance with estimated sensor life and calibration reminders allowing users to ensure their analyser is always up to date. The Is-CA 230 allows for sample conditioning unit for low NOx and high moisture applications.
The Si-CA 230 has a large colour touch screen display which allows users a graphical data display and a customisable gas analysis screen. Data measurements can be shown in real time and controlled via the Sauermann App (available on iOS and Android) up to 15m away.
A number of useful features include one touch pump On/Off with purge and auto pump cut-off should high levels of CO be detected. Stack gas velocity is measurable with the included pitot tube (0 to 99m/s / 0 to 19,500fpm) and draft and differential pressure measurements can also be calculated. The emissions values adjusted for reference O2 with CO and CO2 monitoring possible in ambient air. Storage on the internal memory allows for up top 2,000 measurements to be recorded with up to an 8 hour battery life, the Si-CA 230 is able to withstand a full day in the field before being recharged.
The Si-CA 230 is IP42 providing protection from water spray, with a protective rubber holster and carry case further adding to the protection of the unit both in use and a in storage or transportation.
Sauermann Flue Gas Analyser Comparison
|
Si-CA 030 |
Si-CA 130 |
Si-CA 230 |
LCD Display |
2.8 inches |
4.3 inches |
4.3 inches |
Display resolution |
320 x 240 pixels |
480 x 272 pixels |
480 x 272 pixels |
LCD Display |
No (5 buttons) |
Yes (Plus on/off buttons) |
Yes (Plus on/off buttons) |
Weight |
350g |
350g |
825g |
No of cells |
Up to 3 (O2, CO & NO) |
Up to 3 (O2, CO, NO & Low NO) |
Up to 6 (O2, CO, NO, Low NO, NO2, Low NO2, SO2, Low SO2, CxHy & H2S) |
Max CO measurement |
8,000 ppm |
8,000 ppm |
50,000 ppm (with dilution) |
CO Dilution |
|
|
✔ |
Field replaceable pre calibrated sensors |
|
✔ |
✔ |
Flue gas velocity with pitot tube |
|
✔ |
✔ |
Measurement storage |
Smartphone |
Internal:2000 data points plus smartphone and PC |
Internal:2000 data points plus smartphone and PC |
PC software (Wireless & USB) |
|
✔ |
✔ |
Sauerman Smartphone App |
✔ |
✔ |
✔ |
Combustion applications |
Residential and commercial |
Residential and commercial |
Commercial and Industrial |
Number of gas sensors |
2-3 |
2-3 |
2-6 |
02: 0-25% |
✔ |
✔ |
✔ |
CO: 0-8000ppm |
✔ |
✔ |
|
CO (h2 comp): 0-10,000ppm |
|
|
✔ |
CO (with dilution): 100-50,000ppm |
|
|
✔ |
CO2 (Calculated): 0-99.9% |
✔ |
✔ |
✔ |
NO: 0 - 5,000ppm |
✔ |
✔ |
✔ |
Low NO: 0 - 300ppm |
|
✔ |
✔ |
NO2: 0 - 1,000ppm |
|
|
✔ |
Low NO2: 0 - 100ppm |
|
|
✔ |
NOx (Calculated): 0 - 7,500ppm |
✔ |
✔ |
✔ |
Low NOx (Calculated): 0 - 450ppm |
|
✔ |
✔ |
SO2: 0 - 5,000ppm |
|
|
✔ |
Low SO2: 0 - 100ppm |
|
|
✔ |
CxHy (HC): 0 to 5% |
|
|
✔ |
H2S: 0 to 500ppm |
|
|
✔ |
Flue temperature: -20 to 1250ºC (-4ºF to 2282ºF) |
✔ |
✔ |
✔ |
Air temperature: -40 to 250ºC (-40ºF to 482ºF) |
✔ |
✔ |
✔ |
Differential temperature: -20 to 1250ºC (-4ºF to 2282ºF) |
✔ |
✔ |
✔ |
Pressure/Draft: -200 to 200mbar/-80 to 80 in H20 |
✔ |
✔ |
✔ |
High accuarcy draft: -500 to 500Pa |
|
✔ |
✔ |
Excess air: 0-999% |
✔ |
✔ |
✔ |
Efficiency: 0 to 100% (Gross/HHV) |
✔ |
✔ |
✔ |
Efficiency (condensation): 0 to 125% (Net/LHV) |
✔ |
✔ |
✔ |
Stack Gas Velocity (0 to 99m/s / 0 to 19,500fpm) |
|
✔ |
✔ |
Sauermann Combustion App
The Sauermann Combustion App is a free to download app that is available on both iOS and Android devices. With Wireless connection from the analyser to smartphone, the app allows for remote viewing of combustion data and measurements in real time as either a list or in a graph. Measurement data can be saved and automatic logging is also available. Reports can be created and exported in PDF, CSV (for Excel) and XML formats.
The App allows for databases to be created for customers, operators and equipment.
Key Features
- Combustion analyser allowing for monitoring the emissions of boilers, engines and other combustion appliances
- Kits allowing for combination of gas sensor O2, CO, NO, Low NO, NO2, SO2, CxHy, Low SO2 and H2S
- CO dilution auto range with measurements up to 50,000ppm
- Field replaceable pre calibrated sensors
- iOS and Android Mobile app for real time display and control
- Large colour touch screen
- Data management with automatic logging and report creation
- Predictive maintenance with estimated sensor life and calibration reminders
- One touch pump On/Off with purge
- PC software with wireless and USB connectivity
- Auto pump cut-off for high CO levels
- Graphical data display
- Customisable gas analysis screen
- Sample conditioning unit for low Box and high moisture applications
- Draft and differential pressure measurements
- Emissions values adjusted for reference o@
- CO and CO2 monitoring in ambient air
- Protective rubber holster and IP42 protection rated
- Eight hour battery life
As standard all Sauermann Si-CA 230 Analyser kits include:
- Sauermann Si-CA 230 Multigas Industrial Gas Analyser
- O2 & CO gas sensor
- CO Dilution Auto-range to 50,000ppm
- Protective rubber holster
- 300mm Flue Gas probe with 3m dual hose
- Water trap with filter
- AC power supply/chargerUSB cable
- USB cable
- Mobile app and PC software
- Internal wireless communication module
- Carrying case
- Quick start guide
- Calibration certificate
- CO Dilution Auto-range to 50,000ppm
- USB cable
Each kit option available for the Sauermann Si-CA 230 Analyser comes with the choice of 2,3,4,5 or 6 sensors as shown below:
- Si-CA 230 Kit 2: 2 sensors (O2, CO)
- Si-CA 230 Kit 3N: 3 sensors (O2, CO, NO)
- Si-CA 230 Kit 3NL: 3 sensors (O2, CO, Low range NO)
- Si-CA 230 Kit 4ND: 4 sensors (O2, CO, NO, NO2)
- Si-CA 230 Kit 4NS: 4 sensors (O2, CO, NO, SO2)
- Si-CA 230 Kit 4NC: 4 sensors (O2, CO, NO, CxHy)
- Si-CA 230 Kit 4NLDL: 4 sensors (O2, CO, Low range NO, Low range NO2)
- Si-CA 230 Kit 4NLSL: 4 sensors (O2, CO, Low range NO, SO2 Low Range)
- Si-CA 230 Kit 5NDS: 5 sensors (O2, CO, NO, NO2, SO2)
- Si-CA 230 Kit 5NDC: 5 sensors (O2, CO, NO, NO2, CxHy)
- Si-CA 230 Kit 5NSC: 5 sensors (O2, CO, NO, SO2, CxHy)
- Si-CA 230 Kit 5NSH: 5 sensors (O2, CO, NO, SO2, H2S)
- Si-CA 230 Kit 5NLDLSL: 5 sensors (O2, CO, NO low range, Low range NO2, Low range SO2)
- Si-CA 230 Kit 6NDSC: 6 sensors (O2, CO, NO, NO2, SO2, CxHy)
- Si-CA 230 Kit 6NDSH: 6 sensors (O2, CO, NO, NO2, SO2, H2S)
- Si-CA 230 Kit 6NLDLSLH: 6 sensors (O2, CO, Low range NO, Low range NO2 , Low range SO2, H2S)