DiLOG DL9130EV Multifunction Tester & EVSE Adaptor Kit

SKU
DILOGDL9130EVKIT
  • Includes DL9130EV Multifunction Tester & DLEV1 EVSE Adaptor
  • Specifically designed for engineers performing EV installations
  • Full EV testing sequence for verifying DC protection
More Info

As low as inc VAT £1,198.80 ex VAT £999.00

Pre-order: Expected mid/end June
Choose Your Free Gift
DiLOG DLPK6790 CombiVolt 2 Voltage Indicator Proving Unit Kit
Free
£119.00

Key features:

  • Includes Combivolt 2 Voltage Tester, PU690 Proving Unit and Bag
  • Capable of single or two pole voltage indication up to 650V AC/DC
  • Fully compliant with GS38 and BS 61243-3:2014 regulations
50m R2 Wander Lead
Free
£39.00

Key features:

  • Easy-to-use 50m R2 Wander Reel in a sturdy drum
  • Direct R2 measurement suitable for main earth bond testing
  • Ideal for increasing electrical installation testing efficiency
Di-LOG DL9130EV & EV Adaptor Kit
DiLOG DL9130EV Multifunction Tester & EVSE Adaptor Kit

In stock

Customise DiLOG DL9130EV Multifunction Tester & EVSE Adaptor Kit
1 x DiLOG DL9130EV Multifunction Tester   + inc VAT £0.00 ex VAT £0.00

* Required Fields

Summary

    Product Details

    To celebrate the launch of the DL9130EV Kit, we’ve teamed up with DiLOG to offer our customers the chance to get theirs for FREE. Simply purchase a DL9130EV Kit from Test Meter by 31st August 2022 and you'll be entered into our prizedraw, with one lucky winner getting their money back!

    DiLOG Advanced EV Multifunction Tester & EVSE Adaptor Kit

    The DiLOG Advanced EV Multifunction Tester & EVSE Adaptor Kit is the ideal solution for service engineers looking to offer EV installation and repair to their portfolio. Including both a top of the range MFT and EV charge station adapter, this kit offers everything you will need to perform a variety of safety and operational tests, ensuring installation is in line with BS EN 61557.

    At under £1,000, this kit represents great value for those looking to enter the EV charging installation market. The DL9130EV is a strong addition to their MFT range, featuring a variety of innovative new features to support engineers, while the adaptor provides compatibility with all charge stations and enables an impressive number of safety and operational testing modes.

    DL9130EV Multifunction Tester

    The DL9130EV 18th Edition Multifunction Tester sports an impressive array of features including 6mA pure DC test for RDC-CC verification and a full EV testing sequence for verifying the DC protection provided by the EV charger. Two new and valuable introductions in this model are the Rmax and Zmax features, able to automatically capture maximum values for R1+R2 continuity tests and Zs tests respectively and display them upon test completion.

    RCD test types available using this MFT include AC, A, B and S; auto RCD testing functionality is present for convenience. Other convenient features include auto sensing for high current 2 and 3 wire loop test, enabling the device to detect when users are performing a 2 wire or 3 wire loop/PSCC measurements without the need for mode selection, and an auto start continuity test.

    The inclusion of a colour RGB display on the DL9130EV is a useful addition, as it’s able to visually indicate potential pass/fail conditions. The screen also presents values using large, clear digits and is fully backlit, making viewing easy in low light areas.

    DLEV1 EVSE Adaptor

    The included DiLOG EVSE Charge Station Adaptor is a universal EVSE unit, compatible with all MFTs and all type 1/2 EV plug connectors. This unit features a 13A socket for MFT mains leads and can also be powered through inline load connection, with 4mm input terminals present for use with 3-phase connections.

    The adaptor functions to simulate various test states within the charging unit, including control pilot (CP) and proximity pilot (PP) to ensure proper operation and connection between the unit and vehicle. Error states (including CP error “E”), signal output and load connection can all be tested, alongside Protective Earth (PE) pre-test and PE error.

    DiLOG MFT Options

    Below, you will find a comparison chart outlining the key features of recent DiLOG MFT models.

      DL9110 DL9118 DL9120 DL9130EV
    Continuity Test
    15 mA/200mA Selectable Current      
    R Max (Max R1+R2 recording)      
    Insulation Test 250V, 500V 250V, 500V, 1000V 250V, 500V, 1000V 250V, 500V, 1000V
    Loop Test (3-wire no-trip)
    2-Wire Loop Test    
    Auto Start Loop & Continuity
    Auto Start PFC/PSC (L-PE/L-N)    
    Z Max      
    PFC and PSC Fault Current(L-PE/L-N)
    Phase-Phase Line Test (L-L)  
    RCD Test (AC, A, S-type)
    Auto RCD Test
    RCD Ramp Test
    6 mA RDC-CC (EVSE)      
    Auto EV RCD Test Sequence      
    RCD Test Type B    
    Phase Rotation  
    Intelligent Full Range Protection
    Colour RGB display
    Colour change indicates error
    Remote Test Probe Include    
    Includes calibration certificate
    What's In The Box?
    • Di-LOG DL9130EV Advanced EV 18th Edition Multifunction Tester
    • EVSE Adaptor Complete Kit
    • Padded Neck Strap
    • Professional toolbox style carry case
    • Mains leads
    • 1.2M blue test lead
    • 1.2M red test lead
    • 1.2M green test lead
    • Blue crocodile clip
    • Red crocodile clip
    • Green crocodile clip
    • MN1500 (AA) 1.5v batteries x 6
    • Operating instruction manual
    • Calibration certificate
    More Information
    Specification

    Voltage

    • Display range: 0V - 480V
    • Measuring range: 0V - 480V
    • Resolution: 1V
    • Voltage accuracy: +/- 5% +/- 2digits
    • Frequency range: 45.0Hz – 65.0HzV
    • Frequency accuracy: +/- 1.0Hz

    Continuity

    • Display Range (200mA): 0.01Ω to 2000Ω
    • Measuring Range (200mA): 0.10Ω to 2000Ω
    • Accuracy: +/- 2% +/- 5 digits
    • Resolution: 0.01Ω to 19.99Ω, 20.0Ω to 199.9Ω, 200Ω to 2000Ω
    • Test voltage: >4Vdc >25Vdc Open Circuit
    • Test current: >200mA
    • Display Range (15mA): 0.01Ω to 200Ω
    • Accuracy: +/- 2% +/- 5 digits
    • Resolution: 0.01Ω to 19.99Ω, 20.0Ω to 199.9Ω/>4Vdc >25Vdc Open Circuit/>15mA
    • Compliance: IEC61557-4 and IEC61557-10

    Insulation

    • Display range: 0.01MΩ to 200MΩ
    • Display range: 0.05MΩ to 200MΩ
    • Insulation: +/-5% +/-5 digits
    • Resolution: 0.01MΩ to 1.99MΩ, 2.0MΩ to 19.9MΩ, 20MΩ to 200MΩ
    • Alarm warning: <1MΩ Screen & Audible
    • Test voltage: 250/500/1000V
    • Test voltage specification: -0% +20% (open circuit)
    • Test current: 1mA into UN (1000Ω/V)
    • Compliance: IEC61557-2 and IEC61557-10

    No Trip Loop Impedance

    • Supply voltage: 195-253V, 45Hz – 65Hz
    • Display range: 0.01Ω to 2000Ω
    • Measuring range: 1.00 to 1999Ω (non-trip)
    • Accuracy: +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
    • Resolution: 0.01Ω to 9.99Ω, 10.0Ω to 99.9Ω, 100Ω to 2000Ω
    • Test current: <15mA RMS

    High Current Loop Impedance

    • Supply voltage: 195-253V, 45Hz – 65Hz
    • Display range: 0.01Ω to 2000Ω
    • Measuring range: 0.10Ω to 1999Ω (high current)
    • Accuracy: +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
    • Resolution: 0.01Ω to 9.99Ω, 10.0Ω to 99.9Ω, 100Ω to 2000Ω
    • Test current: 3A RMS

    Loop Test PFC Measurement

    • Display range: 0.1A to 26.0kA
    • Accuracy: +/-5%  +/-5 digits
    • Resolution: 0.1A to 999.9A, 1.0kA to 26.0kA

    High Current Line Impedance

    • Display range: 0.01Ω to 2000Ω
    • Measuring range: 0.10Ω to 2000Ω
    • Accuracy: +/-5% +/-5 digits
    • Resolution: 0.01Ω to 9.99Ω, 10.0Ω to 99.9Ω, 100Ω to 2000Ω
    • Supply voltage: 195V – 253V, 328V – 480V
    • Test current: 3A RMS Peak

    Line Test PSC Measurement

    • Range: 0.1A to 26.0kA
    • Accuracy: +/-5%  +/-5 digits
    • Resolution: 0.1A to 999.9A, 1.0kA to 26.0kA
      • RCD Trip Time Test

        • Supply voltages: 195-253V, 45Hz – 65Hz
        • Nominal test current: 10mA/30mA/100mA ( ½ , 1, 5 I∆n), 300mA/500mA ( ½, 1 I∆n), Variable Mode
        • Variable RCD test: 1mA – 500mA
        • Test current accuracy: -0% +10% at I∆n and 5I∆n, -0% +10% at ½ I∆n
        • Trip time ranges: 0 to 2000ms ½ I∆n, 0ms - 300ms I∆n general, 0ms - 500ms I∆n selective, 0 to 40ms 5 I∆n
        • Trip time accuracy: +/- 5% +/- 2 digits
        • Nominal test current: 10mA/30mA/100mA ( ½ , 1, 5 I∆n), 300mA/500mA ( ½, 1 I∆n)
        • Compliance: IEC61557-6 and IEC61557-10

        RDC-DD Trip Time Test

        • 195-253V, 45Hz – 65Hz
        • 6mA
        • -0% +10%
        • 0 to 10000 I∆n
        • +/- 5% +/- 2 digits
        • 2mA – 10mA
        • IEC61557-6 and IEC61557-10

        RDC (Ramp) Trip Current Test

        • Range: 0.5 I∆n to 1.1 I∆n
        • Accuracy: +/-5% of the expected current
        • Step Size: 0.1*∆n
        • Step duration: 300ms
        • Compliance: IEC61557-6 and IEC61557-10

        Additional Data

        • Weight: 1360g
        • Dimensions: Width 236mm, Depth 130mm, Height 91mm
    1. Kewtech R2 Socket Adaptor
      Kewtech R2 Socket Adaptor SKU: KEWTR2
      inc VAT £19.20 ex VAT £16.00
    2. Kewtech KT103 Wall Socket Checker
      Kewtech KT103 Wall Socket Checker SKU: KEWTKT103
      inc VAT £15.60 ex VAT £13.00
    3. Kewtech Lightmate Kit - All 5 Lightmates
      Kewtech Lightmate Kit - All 5 Lightmates SKU: KEWTLIGHTMATEKIT
      inc VAT £58.20 ex VAT £48.50
    4. Kewtech Testing Accessory Kit 1
      Kewtech Testing Accessory Kit 1 SKU: KEWTACCKIT1
      inc VAT £136.80 ex VAT £114.00
    5. HandyMAN TEK775 Mini AC Earth Leakage Clamp Meter
      HandyMAN TEK775 Earth Leakage Clamp Meter SKU: HANDTEK775
      inc VAT £82.80 ex VAT £69.00
    6. Dilog DL6799 CombiVolt 5 True RMS Electrical Tester
      DiLOG DL6799 CombiVolt 5 True RMS Electrical Tester SKU: DILOGDL6799
      inc VAT £106.80 ex VAT £89.00
    7. Dilog DLLOC1 18th Edition Lockout Kit
      DiLOG DLLOC1 Lockout Kit SKU: DILOGDLLOC1
      inc VAT £26.99 ex VAT £22.49
    8. Dilog DLLOC2 18th Edition Domestic Lockout Kit
      DiLOG DLLOC2 Domestic Lockout Kit SKU: DILOGDLLOC2
      inc VAT £43.19 ex VAT £35.99
    9. Dilog DLLOC3 18th Edition Professional Lockout Kit
      DiLOG DLLOC3 Professional Lockout Kit SKU: DILOGDLLOC3
      inc VAT £60.29 ex VAT £50.24
    10. Dilog DL6518 Earth Leakage Current Clamp Meter
      DiLOG DL6518 Earth Leakage Current Clamp Meter SKU: DILOGDL6518
      inc VAT £144.00 ex VAT £120.00
    11. Dilog CombiVolt Voltage Indicator &amp; Proving Unit Kit DLPK6780
      DiLOG DLPK6780 CombiVolt 1 Voltage Indicator Proving Unit Kit SKU: DILODLPK6780
      inc VAT £130.80 ex VAT £109.00
    12. Dilog PU690 690V AC Proving Unit
      DiLOG PU690 690V AC Proving Unit SKU: DILOPU690
      inc VAT £81.00 ex VAT £67.50
    13. HandyMAN R1 + R2 Jump Leads
      R1 + R2 Jump Leads SKU: HANDTEKJUMP
      inc VAT £12.60 ex VAT £10.50
    14. Dilog DL107 1000V Non-Contact Voltage Detector
      DiLOG DL107 1000V Non-Contact Voltage Detector SKU: DILOGDL107
      inc VAT £17.99 ex VAT £14.99
    15. Dilog DL108 Industrial 1000V Non Contact Voltage Detector
      DiLOG DL108 Industrial 1000V Non Contact Voltage Detector SKU: DILOGDL108
      inc VAT £26.99 ex VAT £22.49
    16. Dilog DLPK6790 CombiVolt 2 Voltage Indicator Proving Unit Kit
      DiLOG DLPK6790 CombiVolt 2 Voltage Indicator Proving Unit Kit SKU: DILODLPK6790
      inc VAT £142.80 ex VAT £119.00
    17. 50m R2 Wander Lead
      50m R2 Wander Lead SKU: TMPTEK50
      inc VAT £46.80 ex VAT £39.00