DiLOG DL9130EV Multifunction Tester & EVSE Adaptor Kit

SKU: DILOGDL9130EVKIT
  • Includes DL9130EV Multifunction Tester & DLEV1 EVSE Adaptor
  • Specifically designed for engineers performing EV installations
  • Full EV testing sequence for verifying DC protection
More Info
£1,198.80 £999.00
In Stock - Available Next Day
Choose Your Free Gift

DiLOG Advanced EV Multifunction Tester & EVSE Adaptor Kit

The DiLOG Advanced EV Multifunction Tester & EVSE Adaptor Kit is the ideal solution for service engineers looking to add EV installation and repair to their portfolio. Including both a top of the range MFT and EV charge station adapter, this kit offers everything you will need to perform a variety of safety and operational tests, ensuring installation is in line with BS EN 61557.

At under £1,000, this kit represents great value for those looking to enter the EV charging installation market. The DL9130EV is a strong addition to their MFT range, featuring a variety of innovative new features to support engineers, while the adaptor provides compatibility with all charge stations and enables an impressive number of safety and operational testing modes.

DL9130EV Multifunction Tester

The DL9130EV 18th Edition Multifunction Tester sports an impressive array of features including 6mA pure DC test for RDC-CC verification and a full EV testing sequence for verifying the DC protection provided by the EV charger. Two new and valuable introductions in this model are the Rmax and Zmax features, able to automatically capture maximum values for R1+R2 continuity tests and Zs tests respectively and display them upon test completion.

RCD test types available using this MFT include AC, A, B and S; auto RCD testing functionality is present for convenience. Other convenient features include auto sensing for high current 2 and 3 wire loop test, enabling the device to detect when users are performing a 2 wire or 3 wire loop/PSCC measurements without the need for mode selection, and an auto start continuity test.

The inclusion of a colour RGB display on the DL9130EV is a useful addition, as it’s able to visually indicate potential pass/fail conditions. The screen also presents values using large, clear digits and is fully backlit, making viewing easy in low light areas.

DLEV1 EVSE Adaptor

The included DiLOG EVSE Charge Station Adaptor is a universal EVSE unit, compatible with all MFTs and all type 1/2 EV plug connectors. This unit features a 13A socket for MFT mains leads and can also be powered through inline load connection, with 4mm input terminals present for use with 3-phase connections.

The adaptor functions to simulate various test states within the charging unit, including control pilot (CP) and proximity pilot (PP) to ensure proper operation and connection between the unit and vehicle. Error states (including CP error “E”), signal output and load connection can all be tested, alongside Protective Earth (PE) pre-test and PE error.

DiLOG MFT Options

Below, you will find a comparison chart outlining the key features of recent DiLOG MFT models.

  DL9110 DL9118 DL9120 DL9130EV
Continuity Test
15 mA/200mA Selectable Current      
R Max (Max R1+R2 recording)      
Insulation Test 250V, 500V 250V, 500V, 1000V 250V, 500V, 1000V 250V, 500V, 1000V
Loop Test (3-wire no-trip)
2-Wire Loop Test    
Auto Start Loop & Continuity
Auto Start PFC/PSC (L-PE/L-N)    
Z Max      
PFC and PSC Fault Current(L-PE/L-N)
Phase-Phase Line Test (L-L)  
RCD Test (AC, A, S-type)
Auto RCD Test
RCD Ramp Test
6 mA RDC-CC (EVSE)      
Auto EV RCD Test Sequence      
RCD Test Type B    
Phase Rotation  
Intelligent Full Range Protection
Colour RGB display
Colour change indicates error
Remote Test Probe Include    
Includes calibration certificate

What's In The Box?

  • Di-LOG DL9130EV Advanced EV 18th Edition Multifunction Tester
  • EVSE Adaptor Complete Kit
  • Padded Neck Strap
  • Professional toolbox style carry case
  • Mains leads
  • 1.2M blue test lead
  • 1.2M red test lead
  • 1.2M green test lead
  • Blue crocodile clip
  • Red crocodile clip
  • Green crocodile clip
  • MN1500 (AA) 1.5v batteries x 6
  • Operating instruction manual
  • Calibration certificate
Specification

Voltage

  • Display range: 0V - 480V
  • Measuring range: 0V - 480V
  • Resolution: 1V
  • Voltage accuracy: +/- 5% +/- 2digits
  • Frequency range: 45.0Hz – 65.0HzV
  • Frequency accuracy: +/- 1.0Hz

Continuity

  • Display Range (200mA): 0.01Ω to 2000Ω
  • Measuring Range (200mA): 0.10Ω to 2000Ω
  • Accuracy: +/- 2% +/- 5 digits
  • Resolution: 0.01Ω to 19.99Ω, 20.0Ω to 199.9Ω, 200Ω to 2000Ω
  • Test voltage: >4Vdc >25Vdc Open Circuit
  • Test current: >200mA
  • Display Range (15mA): 0.01Ω to 200Ω
  • Accuracy: +/- 2% +/- 5 digits
  • Resolution: 0.01Ω to 19.99Ω, 20.0Ω to 199.9Ω/>4Vdc >25Vdc Open Circuit/>15mA
  • Compliance: IEC61557-4 and IEC61557-10

Insulation

  • Display range: 0.01MΩ to 200MΩ
  • Display range: 0.05MΩ to 200MΩ
  • Insulation: +/-5% +/-5 digits
  • Resolution: 0.01MΩ to 1.99MΩ, 2.0MΩ to 19.9MΩ, 20MΩ to 200MΩ
  • Alarm warning: <1MΩ Screen & Audible
  • Test voltage: 250/500/1000V
  • Test voltage specification: -0% +20% (open circuit)
  • Test current: 1mA into UN (1000Ω/V)
  • Compliance: IEC61557-2 and IEC61557-10

No Trip Loop Impedance

  • Supply voltage: 195-253V, 45Hz – 65Hz
  • Display range: 0.01Ω to 2000Ω
  • Measuring range: 1.00 to 1999Ω (non-trip)
  • Accuracy: +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
  • Resolution: 0.01Ω to 9.99Ω, 10.0Ω to 99.9Ω, 100Ω to 2000Ω
  • Test current: <15mA RMS

High Current Loop Impedance

  • Supply voltage: 195-253V, 45Hz – 65Hz
  • Display range: 0.01Ω to 2000Ω
  • Measuring range: 0.10Ω to 1999Ω (high current)
  • Accuracy: +/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)
  • Resolution: 0.01Ω to 9.99Ω, 10.0Ω to 99.9Ω, 100Ω to 2000Ω
  • Test current: 3A RMS

Loop Test PFC Measurement

  • Display range: 0.1A to 26.0kA
  • Accuracy: +/-5%  +/-5 digits
  • Resolution: 0.1A to 999.9A, 1.0kA to 26.0kA

High Current Line Impedance

  • Display range: 0.01Ω to 2000Ω
  • Measuring range: 0.10Ω to 2000Ω
  • Accuracy: +/-5% +/-5 digits
  • Resolution: 0.01Ω to 9.99Ω, 10.0Ω to 99.9Ω, 100Ω to 2000Ω
  • Supply voltage: 195V – 253V, 328V – 480V
  • Test current: 3A RMS Peak

Line Test PSC Measurement

  • Range: 0.1A to 26.0kA
  • Accuracy: +/-5%  +/-5 digits
  • Resolution: 0.1A to 999.9A, 1.0kA to 26.0kA
    • RCD Trip Time Test

      • Supply voltages: 195-253V, 45Hz – 65Hz
      • Nominal test current: 10mA/30mA/100mA ( ½ , 1, 5 I∆n), 300mA/500mA ( ½, 1 I∆n), Variable Mode
      • Variable RCD test: 1mA – 500mA
      • Test current accuracy: -0% +10% at I∆n and 5I∆n, -0% +10% at ½ I∆n
      • Trip time ranges: 0 to 2000ms ½ I∆n, 0ms - 300ms I∆n general, 0ms - 500ms I∆n selective, 0 to 40ms 5 I∆n
      • Trip time accuracy: +/- 5% +/- 2 digits
      • Nominal test current: 10mA/30mA/100mA ( ½ , 1, 5 I∆n), 300mA/500mA ( ½, 1 I∆n)
      • Compliance: IEC61557-6 and IEC61557-10

      RDC-DD Trip Time Test

      • 195-253V, 45Hz – 65Hz
      • 6mA
      • -0% +10%
      • 0 to 10000 I∆n
      • +/- 5% +/- 2 digits
      • 2mA – 10mA
      • IEC61557-6 and IEC61557-10

      RDC (Ramp) Trip Current Test

      • Range: 0.5 I∆n to 1.1 I∆n
      • Accuracy: +/-5% of the expected current
      • Step Size: 0.1*∆n
      • Step duration: 300ms
      • Compliance: IEC61557-6 and IEC61557-10

      Additional Data

      • Weight: 1360g
      • Dimensions: Width 236mm, Depth 130mm, Height 91mm